Abstract

Research has shown CPR quality degrades over time, but little research has been conducted exploring other factors that alter cardiopulmonary resuscitation (CPR) quality. The purpose of this study was to determine if CPR chest compression quality differs overtime when controlling for various factors. 18 CPR certified participants (age=27.88±7.13 years, height=172.51±11.36 cm, mass=77.85±23.12 kg, Body Mass Index (BMI)=26.7±4.71) volunteered. Prior to testing, participants completed multiple fitness tests; Queens College Step test (predicted VO2max), handgrip strength assessment (muscular strength), and maximum push-ups completed in 1 minute (muscular endurance). Participants completed CPR for 7 min on a stimulation manikin (Laerdal QCPR, Stavanger, Norway) that provided data on CPR skill (compression depth, compression release, compression rate) while wearing Polar heart rate monitors (Model H9, Polar, Bethpage, NY).

For compression depth, there was a significant difference across the 7 minutes of CPR being performed (F2.297,36.754=9.727, P=0.001, η2=0.38). Compression depth was also significant when muscular endurance was added as a covariate (F3.553,53.002=3.884, P=0.01, η20.206). All other covariates resulted in results that were insignificant (P>.05).

When analyzing compression release during CPR, there was no significant difference across the 7 minutes (F1.028,16.446=1.259, P=0.28, η2=0.073, 1-β=0.186). There was a difference in compression rate during CPR (F6,90=3.884, P=0.002, η2=0.206). All covariates resulted in results that were insignificant (P>.05). Chest compression depth and number of compressions differed across 7 minutes of CPR suggesting rescuer fatigue. However, differences were negated when some fitness test results were added as covariates.

Faculty Mentor(s)

Dr. Tom Bowman
Dr. Sean Collins
Dr. Emily Evans

Rights Statement

The right to download or print any portion of this material is granted by the copyright owner only for personal or educational use. The author/creator retains all proprietary rights, including copyright ownership. Any editing, other reproduction or other use of this material by any means requires the express written permission of the copyright owner. Except as provided above, or for any other use that is allowed by fair use (Title 17, §107 U.S.C.), you may not reproduce, republish, post, transmit or distribute any material from this web site in any physical or digital form without the permission of the copyright owner of the material.

Share

COinS
 
Apr 6th, 12:00 PM Apr 6th, 1:15 PM

Predicting Cardiopulmonary Resuscitation Quality

Memorial Ballroom, Hall Campus Center

Research has shown CPR quality degrades over time, but little research has been conducted exploring other factors that alter cardiopulmonary resuscitation (CPR) quality. The purpose of this study was to determine if CPR chest compression quality differs overtime when controlling for various factors. 18 CPR certified participants (age=27.88±7.13 years, height=172.51±11.36 cm, mass=77.85±23.12 kg, Body Mass Index (BMI)=26.7±4.71) volunteered. Prior to testing, participants completed multiple fitness tests; Queens College Step test (predicted VO2max), handgrip strength assessment (muscular strength), and maximum push-ups completed in 1 minute (muscular endurance). Participants completed CPR for 7 min on a stimulation manikin (Laerdal QCPR, Stavanger, Norway) that provided data on CPR skill (compression depth, compression release, compression rate) while wearing Polar heart rate monitors (Model H9, Polar, Bethpage, NY).

For compression depth, there was a significant difference across the 7 minutes of CPR being performed (F2.297,36.754=9.727, P=0.001, η2=0.38). Compression depth was also significant when muscular endurance was added as a covariate (F3.553,53.002=3.884, P=0.01, η20.206). All other covariates resulted in results that were insignificant (P>.05).

When analyzing compression release during CPR, there was no significant difference across the 7 minutes (F1.028,16.446=1.259, P=0.28, η2=0.073, 1-β=0.186). There was a difference in compression rate during CPR (F6,90=3.884, P=0.002, η2=0.206). All covariates resulted in results that were insignificant (P>.05). Chest compression depth and number of compressions differed across 7 minutes of CPR suggesting rescuer fatigue. However, differences were negated when some fitness test results were added as covariates.